Modbus Gateways

The Modbus Protocol Translator Gateways have been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of your building automation projects.

The most advanced configuration tool for protocol integration

Intesis MAPS is a Windows based software tool specifically developed to configure and monitor the new generation of Intesis gateways.

Intesis Modbus Gateways

Our solutions are developed for integrators, designed to be robust so they are reliable in the field and easy to set up.

recovery-MAPS

Modbus TCP & RTU

All Modbus gateways can communicate with Modbus TCP and RTU networks at the same time.

 

IO_inverted

Most I/O Modbus functions supported

Use any I/O function code of the wide range supported by Modbus gateways (1x, 2x, 3x, 4x, 5x, 6x, 15x, and 16x).

HMS_web-icon_Drivers_inverted

Multiple data formats

Configure the data length (1, 16, 32, 48 or 64 bits), format (unsigned, signed, float, and bitfield), and byte order (big or little endian).

conversions-MAPS

Polling groups

Improve Modbus communications grouping register requests per device, asking multiple register in a single request.

Modbus logo

Modbus Protocol is a messaging structure developed by Modicon in 1979. It is used to establish master-slave/client-server communication between intelligent devices. For this reason, it is used in innumerable gas and oil and substation applications. But Modbus is not only an industrial protocol. Building, infrastructure, transportation and energy applications also make use of its benefits.

For further information, please visit modbus.org

Intesis is a Modbus member

Modbus Protocol Translators

Bring connectivity to you Modbus management system thanks to Intesis Modbus solutions. Connect BACnet, KNX, LonWorks, DALI or M-BUS devices to Modbus systems and extend your building management system capabilities.

Intesis Modbus can act as Modbus RTU device, Modbus TCP device or both.

On the Modbus server versions, the gateway provides server functionality to the BMS or Modbus controller over Modbus TCP through the Ethernet port and over Modbus RTU through the serial port (EIA485 or EIA232).

On the Modbus client versions, the gateway provides client functionality to control Modbus TCP server devices through Ethernet and Modbus RTU devices through the serial port. In such cases, control and monitoring of Modbus devices from BACnet and KNX BMS controllers is possible.


  • Great integration flexibility thanks to KNX TP, RS485, Ethernet, DALI or M-Bus interfaces.
  • Scaled licences per number of datapoints help finding the right gateway version for your project.
  • Modbus advanced functionalities to improve internal and external protocol communications.
  • Modbus template repository with most common Modbus devices and template generator to create your own template devices.

More information related to these products


Software

Intesis MAPS

The Most advanced configuration tool for protocol integration. Inspect communications between protocols and get control.
Download

Get Intesis MAPS

Just configure and monitor the new generation of Intesis Gateways. Click to download the configuration software.
Features

Templates to make it easy

Take advantage with Intesis MAPS. The new templates feature helps to make the integration easier and faster.
History

Intesis Gateways' R-Evolution

Since 2.000 we have been providing the most advanced communication gateway solutions for different automation systems integration.