Check out our wide range of IntesisBox solutions and gateways.

Make sure that you don’t miss anything from your building thanks to IntesisBox gateways and its great flexibility for integration. Simply decide which is the best BMS (Building Management System) you need and the actuators and sensors that best fits your project and do not worry how the will speak to each other: that is our task! With IntesisBox gateways, you will be able to integrate many different standard protocols between them, such as ASCII, BACnet, EnOcean, KNX, LonWorks, Modbus or Wi-Fi.

Building Management defines the complete automation of nowadays buildings embedded with high technology. This solution consists of a software and hardware in charge of monitoring, control and report the management of equipment and building services; usually it is implemented in large projects with large electrical and Air Conditioning systems.

Because it helps reducing and improving the efficiency of global and centralized energy consumption, it is an essential component in the energy management of buildings. This solution allows us exhaustive control and monitoring, locally or remotely, of each room of the building individually and all of them in general.

This control is not limited to Air Conditioners, but extended to control security systems, access doors, lighting, presence detectors, electrical supplies and elevators, among others.

Building Management also helps providing statistics and logs of all devices connected to the system; this possibility allows us to take better decisions and reprogram the devices accordingly to the data collected to improve its operations.

Because of the importance of Building Management and the vast possibilities that it offers to the current buildings, IntesisBox has a large portfolio of gateways for an integrated approach to building management. These gateways help to improve the building efficiency while integration time and security risks are reduced.

There are different protocols available to operate this solution, IntesisBox offers gateways in these protocols: BACnet, KNX, Modbus, OPC, LonWorks, EnOcean and ASCII.

Applications for IntesisBox gateways in Building Management are not only for large buildings, but also for residential and commercial sites too.

Where can we apply IntesisBox gateways?

Basically, IntesisBox gateways can be used to integrate the following devices, sensors and technologies to any BMS (Building Management System)

Automation
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
BACnet - - - - - - IBOX-MBS-BAC
- -
Modbus MBM - IBOX-BAC-MBM
- - IBOX-KNX-MBM
- - - -
Modbus RTU - IBOX-BAC-MBRTU
- - IBOX-KNX-MBRTU
- IBOX-MBS-TCP2RTU
- -
Building Management
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ASCII - - - USB-ENO-ASCII-U/C
USB-ENO-ASCII/C
- - - - -
BACnet IBOX-ASCII-BAC
- - - IBOX-KNX-BAC
- IBOX-MBS-BAC
- -
EnOcean - - - - IBOX-KNX-ENO-A1/C
- - - -
KNX IBOX-ASCII-KNX
IBOX-BAC-KNX
- - - IBOX-LON-KNX
IBOX-MBS-KNX
- -
LonWorks IBOX-ASCII-LON
- - - IBOX-KNX-LON
- IBOX-MBS-LON
- -
Modbus MBM - - - - IBOX-KNX-MBM
- - - -
Modbus RTU - - - - IBOX-KNX-MBRTU
- IBOX-MBS-TCP2RTU
- -
Modbus TCP - - - - IBOX-KNX-MBTCP
- - - -
Energy Measurement
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
M-BUS - IBOX-BAC-MBUS
- - - - IBOX-MBS-MBUS
- -
Modbus MBM - - - - IBOX-KNX-MBM
- - - -
Modbus RTU - - - - IBOX-KNX-MBRTU
- - - -
Fire Protection
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
Algorex - - - - - - IBOX-MBS-ALGOREX
- -
Algorinet - - - - - - IBOX-MBS-ALGORI
- -
Cerberus - - - - - - IBOX-MBS-CERBERUS
- -
FC330A - - - - - - IBOX-MBS-FC330A
- -
Kilsen - - - - - - IBOX-MBS-KILSEN
- -
NID3000 - IBOX-BAC-NID3000
- - - - IBOX-MBS-NID3000
IS-OPC-NID3K
-
Hotel Management
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
DALI - IBOX-BAC-DALI
- - - - - - -
Fidelio - IBOX-BAC-FID
- - - - IBOX-MBS-FID-A/B
- -
HVAC
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
Arçelik AC - - - - AK-AC-KNX-4/8/16/64
- - - -
Daikin AC - - DK-AC-BAC-1
DK-AC-ENO-1/1C
DK-AC-KNX-1i
DK-AC-KNX-1
- DK-AC-MBS-1
- DK-AC-WMP-1
Daikin RC - - DK-RC-BAC-1
DK-RC-ENO-1i/1iC
DK-RC-KNX-1i
DK-RC-KNX-1
- DK-RC-MBS-1
- DK-RC-WMP-1
Fujitsu RC - - - - FJ-RC-KNX-1i
- FJ-RC-MBS-1
- FJ-RC-WMP-1
Hisense RC - - - - - - HS-RC-MBS-1
- -
Hitachi AW - - - - HI-AW-KNX-1
- - - -
Hitachi RC - HI-AC-BAC-8/64
- - - - HI-RC-MBS-1
- -
IR - - - - IS-IR-KNX-1i
- - - IS-IR-WMP-1
LG AC - - - - LG-AC-KNX-4/8/16/64
- LG-AC-MBS-4/8/32/64
- -
LG RC - - - - LG-RC-KNX-1i
- LG-RC-MBS-1
- LG-RC-WMP-1
Midea AC - - - - MD-AC-KNX-1B/16/64
- MD-AC-MBS-1/4/8/32
- -
Mitsubishi Electric AC - - ME-AC-BAC-1
ME-AC-ENO-1/1C
ME-AC-KNX-15/100
ME-AC-KNX-1i
ME-AC-KNX-1-V2
ME-AC-LON-1
ME-AC-MBS-1
ME-AC-MBS-50/100
- ME-AC-WMP-1
Mitsubishi Heavy Ind AC - - - - MH-AC-KNX-48/128
- MH-AC-MBS-48/128
- -
Mitsubishi Heavy Ind RC - - MH-RC-BAC-1
MH-RC-ENO-1i/1iC
MH-RC-KNX-1i
- MH-RC-MBS-1
- MH-RC-WMP-1
Panasonic AC - PA-AC-BAC-64/128
PA-AC-BAC-1
PA-AC-ENO-1i/1iC
PA-AC-KNX-64/128
PA-AC-KNX-1i
- PA-AC-MBS-64/128
PA-AC-MBS-1
- PA-AC-WMP-1
Panasonic AW - - - - PA-AW2-KNX-1
PA-AW-KNX-1
- PA-AW-MBS-1
PA-AW2-MBS-1
- -
Panasonic RC - - PA-RC2-BAC-1
- PA-RC-KNX-1i
- - - -
Panasonic RC2 - - - - PA-RC2-KNX-1i
- PA-RC2-MBS-1
- PA-RC2-WMP-1
Samsung NASA AC - - - - SM-ACN-KNX-4/8/16/64
- SM-ACN-MBS-4/8/32/64
- -
Samsung NO NASA RC - - - - - - SM-RC-MBS-1
- -
Toshiba AC - - - - TO-AC-KNX-16/64
- - - -
Toshiba RC - - TO-RC-BAC-1
- TO-RC-KNX-1i
- TO-RC-MBS-1
- TO-RC-WMP-1
Intrusion Detection System
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
SIA - - - - - - IBOX-MBS-GALAXY
- -
Lighting Control
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
DALI - IBOX-BAC-DALI
- - - - IBOX-MBS-DALI
- -
Multiprotocol Integration
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ASCII - - - USB-ENO-ASCII-U/C
USB-ENO-ASCII/C
- - - - -
BACnet IBOX-ASCII-BAC
- - - IBOX-KNX-BAC
- IBOX-MBS-BAC
- -
Daikin AC - - - - - - - - DK-AC-WMP-1
Daikin RC - - - - - - - - DK-RC-WMP-1
EnOcean - - - - IBOX-KNX-ENO-A1/C
- - - -
Fidelio - IBOX-BAC-FID
- - - - - - -
Fujitsu RC - - - - - - - - FJ-RC-WMP-1
IR - - - - - - - - IS-IR-WMP-1
KNX IBOX-ASCII-KNX
IBOX-BAC-KNX
- - - IBOX-LON-KNX
IBOX-MBS-KNX
- -
LG RC - - - - - - - - LG-RC-WMP-1
LonWorks IBOX-ASCII-LON
IBOX-BAC-LON
- - IBOX-KNX-LON
- IBOX-MBS-LON
- -
M-BUS - IBOX-BAC-MBUS
- - - - IBOX-MBS-MBUS
- -
Mitsubishi Electric AC - - - - - - - - ME-AC-WMP-1
Mitsubishi Heavy Ind RC - - - - - - - - MH-RC-WMP-1
Modbus MBM - IBOX-BAC-MBM
- - IBOX-KNX-MBM
- - - -
Modbus RTU - IBOX-BAC-MBRTU
- - IBOX-KNX-MBRTU
- IBOX-MBS-TCP2RTU
- -
Modbus TCP - IBOX-BAC-MBTCP
- - IBOX-KNX-MBTCP
- - - -
Panasonic AC - - - - - - - - PA-AC-WMP-1
Panasonic RC2 - - - - - - - - PA-RC2-WMP-1
Toshiba RC - - - - - - - - TO-RC-WMP-1
Solar Power Systems
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ATERSA - - - - - - IBOX-MBS-ATERSA
- -
SUNWAYS - IBOX-BAC-SUNWAYS
- - - - - - -
Wireless Integration
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ASCII - - - USB-ENO-ASCII-U/C
USB-ENO-ASCII/C
- - - - -
Daikin AC - - - - - - - - DK-AC-WMP-1
Daikin RC - - - - - - - - DK-RC-WMP-1
Fujitsu RC - - - - - - - - FJ-RC-WMP-1
IR - - - - - - - - IS-IR-WMP-1
LG RC - - - - - - - - LG-RC-WMP-1
Mitsubishi Electric AC - - - - - - - - ME-AC-WMP-1
Mitsubishi Heavy Ind RC - - - - - - - - MH-RC-WMP-1
Panasonic AC - - - - - - - - PA-AC-WMP-1
Panasonic RC2 - - - - - - - - PA-RC2-WMP-1
Toshiba RC - - - - - - - - TO-RC-WMP-1
USB - - - USB-ENO/C
- - - - -