HVAC Compatibility tool

Find the appropriate solution for your Air Conditioner brand to get the most out of your AC system.

Mitsubishi Electric AC brand Solution

Find your AC integration solution developed jointly with Mitsubishi Electric. Following its specifications provided ensure the compatibility as a major factor to enable maximum efficiency.
HMS_web-icon_Backup

Ensure energy savings

Intesis AC gateways allow to reduce considerably the energy consumption of buildings while contributing to environment protection.

HMS_web-icon_Solution Partner

Improve user's comfort

The goal is to reduce energy while improving user’s comfort. With Intesis these are not mutually exclusive outcomes!

fan-and-vane

Leading with leaders

We are the indisputable market leader in AC integration thanks to have the continuous support of the major AC manufacturers.

Mitsubishi Electric Domestic, Mr.Slim and City Multi to BACnet MS/TP Interface

The Mitsubishi Electric-BACnet gateway allows fully bi-directional communication between Mitsubishi Electric Domestic, Mr.Slim and City Multi Air Conditioner units and BACnet or MS/TP networks.

FEATURES

  • BTL mark ensures full interoperability with BACnet devices.
  • Support only BACnet MS/TP.
  • Configuration from onboard DIP-switches.
  • Quick and easy installation (plug and set the DP-SW).
  • External power not required.
  • Simultaneous control of the AC unit by the manufacturer’s remote controller and BACnet MS/TP.
  • Reduced dimensions 93 x 53 x 58 mm.
  • Mountable on DIN rail, wall, or even inside the indoor unit in some models of AC.
  • Abstraction of Air Conditioning unit properties and functionalities as fixed BACnet Objects.
  • Occupancy function allows energy savings. Costs related to HVAC systems in a building are one of the highest and this type of functions allow to reduce them.
  • Total control and monitoring of the AC unit from BACnet, including AC unit’s internal variables, running hours counter (for filter maintenance control) and error indication.
  • Supports silent mode and horizontal vanes control.
mitsubishi-electric-domestic-slim-city-multi-bacnet-mstp-interface

Use Case

Integration of Mitsubishi Electric Domestic, Mr. Slim & City Multi lines into a BACnet installation.

ME-AC-BAC-1L

Description

DIRECT CONNECTION TO INDOOR UNITS

The gateway is wired directly to the indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the monitoring of errors, alarms and some internal variables.

FAST AND EASY TO SET UP BY DIP-SW

The product can be installed and set up in a really short time. It’s only a matter of wiring the gateway to the AC unit and configure the DIP-SW accordingly. No configuration software and no power supply are required.

Technical Documentation

User ManualGeneral information about this productDownload
Installation ManualLearn how to install the device in your projectDownload
EDEDownload EDE fileDownload
HVAC Compatibility toolFind the appropriate solution for your HVAC integrationOpen
HVAC CompatibilityCheck your HVAC compatibilityDownload
BTL CertificationCheck the product certificationDownload
BACnet MS/TP Server PIC StatementBACnet MS/TP Server Protocol Implementation Conformance StatementDownload
EC Declaration of ConformityCheck the product certificationDownload
Tender Specification DocumentProduct details for tender submittalDownload
Recommendations to avoid polarity issuesHow to avoid polarity issues in RS485 NetworksLearn more

Commercial Documentation

Marketing Datasheet Discover all the integration solutions for Mitsubishi Electric
Download
Intesis Brochure
Know more about the Intesis current available products
Download

HVAC Compatibility

Ensure the compatibility of this gateway with your AC model by visiting https://compatibility.intesis.com/

Compatible AC models

MFZ-KA | MFZ-KJ | MLZ-KA | MLZ-KP-NA | MSY-A | MSY-GL | MSZ-A | MSZ-AP - VG-E1 | MSZ-AP - VG-EN1 | MSZ-AP - VGK-E1 | MSZ-AP - VGK-EN1 | MSZ-CGE | MSZ-DM | MSZ-EF | MSZ-FA | MSZ-FD | MSZ-FH | MSZ-GA | MSZ-GB | MSZ-GC | MSZ-GE | MSZ-GF | MSZ-GL | MSZ-HR | MSZ-HA | MSZ-HC | MSZ-HJ | MSZ-LN | MSZ-SF | MSZ-WN | PCA-M | PCA-RP | PCA-RP – HA | PCA-RP – HAQ | PEAD-A - AA5 | PEAD-RP | PEAD-SP | PEAD-SM - JA | PEAD-SM - JAL | PEAD-M - JA | PEAD-M - JAL | PEY-P - JA | PEAM125GAA | PLA-RP - | PLA-ZM - | PLA-ZRP - | PLA-SM - | PLA-M-EA-A | PLY-P-BA | PKA-M - | PKA-RP - | PSA-RP - | SEZ-KA - | SEZ-KC - | SEZ-KD - | SEZ-M - | SLZ-KA - | SLZ-KF - | SLZ-M - | PEA-RP - | PEH-RP - | PCFY-P - VKM-ER1 (since end 2013) | PEFY-P - NMAU-E3 | PEFY-P - NMHSU-E (since end 2013) | PEFY-P - VMA-E | PEFY-P - VMA-E2 | PEFY-P - VMA-ER3 (since end 2013) | PEFY-P - VMAL-E | PEFY-P - VMAL-E2 | PEFY-P - VMH(S)-E (since end 2013) | PEFY-P - VMR-E (since end 2013) | PEFY-P - VMS1-E (since end 2013) | PFFY-P - VKM-E2 (since end 2013) | PFFY-P - VLRMM-E (since end 2013) | PKFY-P - VBM-ER3 | PKFY-P - VHM-ER2 (since end 2013) | PKFY-P - VKM-ER1 (since end 2013) | PLFY-P - VBM-E (since end 2013) | PLFY-P - VBM-ER3 (since end 2013) | PLFY-P - VEM-E | PLFY-P - VCM-ER2 (since end 2013) | PLFY-P - VFM-E | PLFY-P - VFM-E1 | PLFY-P - VLDM-E (since end 2013) | PMFY-P - VBM-E#2 | PMFY-P - VBM-ER3 | PMFY-P - VBM-ER4 (since end 2013) | PLFY-WP - VFM-E | PLFY-WP - VFM-E1 | PLFY-WP - VBM-E | PEFY-WP - VMA-E | PEFY-WP - VMS1-E | PFFY-WP - VLRMM-E | MSY-D | MSY-GA | MSY-GE | MSZ-D | MSZ-FE | MS-A | PCA-A | PEA-A | PEAD-A | PKA-A | PLA-A | PVFY-P - E00 (since end 2012) | PCFY-P - NKMU-ER1.TH (since end 2012) | PEFY-P - NMSU-ER2.TH (since end 2012) | PEFY-P - NMAU-E | PEFY-P - NMAU-E2 (since end 2012) | PEFY-P - NMAU-E3 (since end of 2013) | PEFY-P - NMHSU-E (since end 2012) | PEFY-P - NMHU-E (since end 2012) | PEFY-P - NMHU-E2 (since end of 2013) | PFFY-P - NEMU-E (since end 2012) | PFFY-P - NRMU-E (since end 2012) | PKFY-P - NBMU-E2 (since end 2012) | PKFY-P - NHMU-E2 (since end 2012) | PKFY-P - NKMU-E2.TH (since end 2012) | PLFY-P - NBMU-ER2 (since end 2012) | PLFY-P - NCMU-ER4.TH (since end 2012) | PLFY-P - NFMU-E | PMFY-P - NBMU-ER5 (since end 2012) | PVFY-P - NAMU-E | MSXY-FD | SL - AKLR | PL - BAK | PK - FAKLD | PC - GAKD | PS - GAKD | SE - AKR | SE - AKLR | PE - EAK | PE - EAKT | PEH - EAK | PEH - EAKH | PED - AAK | PLFY-P - EMG6 | PK - GAKLD | PE - GAK | PE - GAKT | PKH - GAKL | PKH - FAK | PCH - GAK | PSH - GAK | PE(H) - EAK | MSC-GA - VB | PCFY-P100VKM-E | PCFY-P125VKM-E | PCFY-P40VKM-E | PCFY-P63VKM-E | PEFY-M100 VMA2-A | PEFY-M100 VMA-A | PEFY-M125 VMA2-A | PEFY-M125 VMA-A | PEFY-M140 VMA-A | PEFY-M20 VMA2-A | PEFY-M20 VMA-A | PEFY-M25 VMA2-A | PEFY-M25 VMA-A | PEFY-M32 VMA2-A | PEFY-M32 VMA-A | PEFY-M40 VMA2-A | PEFY-M40 VMA-A | PEFY-M50 VMA2-A | PEFY-M50 VMA-A | PEFY-M63 VMA2-A | PEFY-M63 VMA-A | PEFY-M71 VMA2-A | PEFY-M71 VMA-A | PEFY-M80 VMA2-A | PEFY-M80 VMA-A | PEFY-P100VMA3-E | PEFY-P100VMHS2-E P | PEFY-P100VMHS-E | PEFY-P125VMA3-E | PEFY-P125VMHS-E | PEFY-P125VMHS-E-F | PEFY-P140VMHS-E | PEFY-P15VMS1-E | PEFY-P200VMHS-E | PEFY-P200VMHS-E-F | PEFY-P20VMA3-E | PEFY-P20VMR-E-L | PEFY-P20VMS1-E | PEFY-P250VMHS-E | PEFY-P250VMHS-E-F | PEFY-P25VMA3-E | PEFY-P25VMR-E-L | PEFY-P25VMS1-E | PEFY-P32VMA3-E | PEFY-P32VMR-E-L | PEFY-P32VMS1-E | PEFY-P40VMA3-E | PEFY-P40VMHS-E | PEFY-P40VMS1-E | PEFY-P50VMA3-E | PEFY-P50VMHS2-E | PEFY-P50VMHS-E | PEFY-P50VMS1-E | PEFY-P63VMA3-E | PEFY-P63VMHS2-E | PEFY-P63VMHS-E | PEFY-P63VMS1-E | PEFY-P71VMA3-E | PEFY-P71VMHS2-E | PEFY-P71VMHS-E | PEFY-P80VMA3-E | PEFY-P80VMHS2-E | PEFY-P80VMHS-E | PFFY-P20VCM-E | PFFY-P20VKM-E | PFFY-P20VLEM-E | PFFY-P20VLRM-E | PFFY-P25VCM-E | PFFY-P25VKM-E | PFFY-P25VLEM-E | PFFY-P25VLRM-E | PFFY-P32VCM-E | PFFY-P32VKM-E | PFFY-P32VLEM-E | PFFY-P32VLRM-E | PFFY-P40VCM-E | PFFY-P40VKM-E | PFFY-P40VLEM-E | PFFY-P40VLRM-E | PFFY-P50VCM-E | PFFY-P50VLEM-E | PFFY-P50VLRM-E | PFFY-P63VCM-E | PFFY-P63VLEM-E | PFFY-P63VLRM-E | PKFY-P100VKM-E | PKFY-P10VLM-E | PKFY-P15VLM-E | PKFY-P20VLM-E | PKFY-P25VLM-E | PKFY-P32VLM-E | PKFY-P40VLM-E | PKFY-P50VLM-E | PKFY-P63VKM-E | PKFY-WL10VLM | PKFY-WL15VLM | PKFY-WL20VLM | PKFY-WL25VLM | PKFY-WL32VLM | PLFY-EP50VEM-E | PLFY-EP63VEM-E | PLFY-EP80VEM-E | PLFY-M100VEM-E | PLFY-M125VEM-E | PLFY-M20VEM-E | PLFY-M25VEM-E | PLFY-M32VEM-E | PLFY-M40VEM-E | PLFY-M50VEM-E | PLFY-M63VEM-E | PLFY-M80VEM-E | PLFY-P100VLMD-E | PLFY-P125VLMD-E | PLFY-P15VFM-E | PLFY-P20VFM-E | PLFY-P20VLMD-E | PLFY-P25VFM-E | PLFY-P25VLMD-E | PLFY-P32VFM-E | PLFY-P32VLMD-E | PLFY-P40VFM-E | PLFY-P40VLMD-E | PLFY-P50VFM-E | PLFY-P50VLMD-E | PLFY-P63VLMD-E | PLFY-P80VLMD-E | PMFY-P20VBM-E | PMFY-P25VBM-E | PMFY-P35VBM-E | PMFY-P40VBM-E | MFZ-KJ25VE | MFZ-KJ35VE | MFZ-KJ50VE | MFZ-KT25VG | MFZ-KT35VG | MFZ-KT50VG | MFZ-KT60VG | MLZ-KP25VF | MLZ-KP35VF | MLZ-KP50VF | MSY-TP35VF | MSZ-AP15VG | MSZ-AP20VG | MSZ-AP25VG | MSZ-AP25VGK | MSZ-AP35VGK | MSZ-AP42VG | MSZ-AP42VGK | MSZ-AP50VGK | MSZ-AP60VGK | MSZ-AP71VGK | MSZ-BT1 | MSZ-DM35VA | MSZ-EF18VGK W/B/S | MSZ-EF22VGK W/B/S | MSZ-EF25VGK W/B/S | MSZ-EF35VGK W/B/S | MSZ-EF42VGK W/B/S | MSZ-EF50VGK W/B/S | MSZ-FH25VE | MSZ-FH35VE | MSZ-FH50VE | MSZ-HR25VF | MSZ-HR35VF | MSZ-HR42VF | MSZ-HR50VF | MSZ-LN18VG W | MSZ-LN18VG2 V/B/R | MSZ-LN18VG2 W | MSZ-LN25VG2 V/B/R | MSZ-LN25VG2 W | MSZ-LN35VG2 V/B/R | MSZ-LN35VG2 W | MSZ-LN50VG2 V/B/R | MSZ-LN50VG2 W | MSZ-LN60VG2 V/B/R | MSZ-LN60VG2 W | MSZ-SF15VA | MSZ-SF20VA | MSZ-SF25VE | MSZ-SF35VE | MSZ-SF42VE | MSZ-SF50VE | MUSY-TP35VF | MUSY-TP50VF | MXZ-4E72VA-E2 | SEZ-M25DA | SEZ-M35DA | SEZ-M50DA | SEZ-M60DA | SEZ-M71DA | SLZ-M15FA | SLZ-M25FA | SLZ-M35FA | SLZ-M50FA | SLZ-M60FA | PCA-M100KA | PCA-M125KA | PCA-M140KA | PCA-M35KA | PCA-M50KA | PCA-M71KA | PCA-M80KA | PEAD-M125JA | PEAD-M140JA | PEAD-M35JA | PEAD-M50JA | PEAD-M71JA | PEAD-M80JA | PEA-RP200VVKA | PEA-RP250VVKA | PEA-RP250WKA | PKA-M100KAL | PKA-M35HAL | PKA-M50HAL | PKA-M71KAL | PKA-M80KAL | PLA-M100EA | PLA-M125EA | PLA-M140EA | PLA-M35EA | PLA-M50EA | PLA-M60EA | PLA-M71EA | PLA-ZM100EA | PLA-ZM125EA | PLA-ZM140EA | PLA-ZM35EA | PLA-ZM50EA | PLA-ZM60EA | PLA-ZM71EA | PSA-M100KA | PSA-M125KA | PSA-M140KA | PSA-RP100KA | PSA-RP125KA | PSA-RP140KA | PSA-RP71KA

* The asterisks stand for any character in the asterisk' position.

1The CN105 port of this AC unit is already in use for the WiFi interface included with the AC unit. To use any of our solutions connectable to CN105 port, this WiFi must be disconnected and cannot be used at the same time.

    File Type Version Size Read online  

ORDER CODE:

IN485MIT001I000 Mitsubishi Electric Domestic, Mr.Slim and City Multi to BACnet MS/TP Interface - 1 unit

 

For older version, please click here to find the documentation

INCLUDED COMPONENTS:

  • Intesis Gateway.
  • Installation Manual.
  • AC Connection cable.

Warranty: 36 months.

Gateways for Mitsubishi Electric AC systems integration

The Intesis portfolio includes a wide variety of gateways for the integration of Mitsubishi Electric Air Conditioners into the most popular building automation standard protocols.


In 2006, Intesis launched the first product able to integrate Mitsubishi Electric AC Systems into KNX that, shortly afterwards, was certified by the KNX organization. Now, after years of experience, the products from Intesis make it easy to meet Mitsubishi Electric integration units with the most extended standards protocols (Modbus, BACnet and Wi-Fi).

From the automation side, it does not matter the model of your Mitsubishi Electric unit: Domestic and Mr.Slim and City Multi AC units are supported with Intesis gateways.

Check out your model in our HVAC compatibility tool and start working with Intesis solutions for Mitsubishi Electric air conditioner units.

Connected to


Mitsubishi Electric Indoor Units


Mitsubishi-Electric-AC-indoor-unit-solution-scheme
Mitsubishi-Electric-one-to-one-Air-Conditioner-Interfaces-showcase

Your one to one solution for Mitsubishi Electric Domestic, Mr. Slim and City Multi AC units. Direct connection from Intesis device to CN105 port in AC indoor unit. Wire to CN105 connector is provided.

BACnet logo
KNX logo
Modbus logo
ASCII-WiFi logo 25

Mitsubishi Electric centralized controllers


Mitsubishi-Electric-AC-centralized-controllers-solution-scheme
Outdoor-units-Air-Conditioner-Interfaces-showcase

Your solution for Mitsubishi Electric City Multi VRF systems. Direct connection to Mitsubishi Electric centralized controllers via IP connection. Up to 100 Mitsubishi Electric City Multi groups with only one Intesis gateway.

BACnet logo
KNX logo
Modbus logo
ASCII-WiFi logo 25