HVAC Compatibility tool

Find the appropriate solution for your Air Conditioner brand to get the most out of your AC system.

Mitsubishi Heavy Industries AC brand Solution

Find your AC integration solution developed jointly with Mitsubishi Heavy Industries. Following its specifications provided ensure the compatibility as a major factor to enable maximum efficiency.
HMS_web-icon_Backup

Ensure energy savings

Intesis AC gateways allow to reduce considerably the energy consumption of buildings while contributing to environment protection.

HMS_web-icon_Solution Partner

Improve user's comfort

The goal is to reduce energy while improving user’s comfort. With Intesis these are not mutually exclusive outcomes!

fan-and-vane

Leading with leaders

We are the indisputable market leader in AC integration thanks to have the continuous support of the major AC manufacturers.

Mitsubishi Heavy Industries FD and VRF systems to KNX Interface with Binary Inputs

The Mitsubishi Heavy Industries-KNX gateway allows fully bi-directional communication between Mitsubishi Heavy Industries FD and VRF systems and KNX installations.

Additionally, four potential-free binary inputs provide the possibility to integrate external devices, such as window contacts or presence detectors, that allows launching internal functions focused to improve energy efficiency.

FEATURES

  • KNX certified.
  • Configured by ETS standard configuration tool.
  • Reduced dimensions allowing a quick installation inside the Air Conditioner unit.
  • Offered all the required DPT objects to be compatible with all KNX thermostats in the market.
  • Energy efficiency functions, such as “timeout”, “open window” or “Occupancy”. Costs related to HVAC systems in a building are one of the highest and these functions allow to reduce them.
  • Smooth integration of KNX thermostats allowing the control of the AC unit by the own temperature sensor of the thermostat.
  • Simultaneous control of the AC unit by the IR remote controller and by KNX.
  • Total control and monitoring of the AC unit from KNX, including AC unit’s internal variables, running hours counter (for filter maintenance control) and error indication.
  • Up to 5 scenes can be saved and executed from KNX.
mitsubishi-heavy-industries-fd-vrf-knx-binary-inputs-interface

Use Case

Integration of Mitsubishi Heavy Industries Air Conditioner Units into a KNX installation with Binary Inputs.

MH-RC-KNX-1i

 

Description

DIRECT CONNECTION TO INDOOR UNITS

The gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the monitoring of errors, alarms and some internal variables.

EASY TO SET UP BY ETS (STANDARD KNX TOOL)    

The connection between the two networks is quickly set up in the ETS configuration tool using the product database available to download. Thanks to the high number of supported KNX DPTs and the KNX certification, the gateway ensures interoperability with any KNX device in the market.

Technical Documentation

User ManualGeneral information about this productDownload
Installation ManualLearn how to install the device in your projectDownload
HVAC Compatibility toolFind the appropriate solution for your HVAC integrationOpen
HVAC CompatibilityCheck your HVAC compatibilityDownload
EC Declaration of ConformityCheck the product certificationDownload
Tender Specification DocumentProduct details for tender submittalDownload

Programming Tool

ETS Data Base Configuration tool Download

Commercial Documentation

Marketing Datasheet Discover all the integration solutions for Mitsubishi Heavy Industries
Download
Intesis Brochure
Know more about the Intesis current available products
Download

HVAC Compatibility

Ensure the compatibility of this gateway with your AC model by visiting https://compatibility.intesis.com/

Compatible AC models

SRR - ZJ-S | SRR - ZM-S | SRF - ZIX-S | SRF - ZJX-S | SRF - ZMX-S | SRF - ZMXA-S | DXK - ZJ-S | DXK - ZL-S | DXK - ZM-S | DXK - ZMA-S | DXK - ZSA-W | DXK - ZRA-W | SRK - CTB* | SRK - HE-S1 | SRK24YMA-S | SRK24YRA-W | SRK - YSA-W | SRK - ZG-S | SRK - ZHX-S | SRK - ZIX-S | SRK - ZJ-S | SRK - ZJ-S1 | SRK - ZJR-S | SRK - ZJX-S | SRK - ZJX-S1 | SRK - ZK-S | SRK - ZL-S | SRK - ZM-S | SRK - ZMA-S | SRK - ZMX-S | SRK - ZMXA-S | SRK - ZR-S | SRK - ZRA-W | SRK - ZS-S | SRK - ZS-W | SRK - ZS-WT | SRK - ZS-WB | SRK - ZR-W | SRK - ZS - | SRK - ZSA-W | SRK - ZSPR-S | SRK - ZSX-S | SRK - ZSX-WT | SRK - ZSXA-WB | SRK - ZSXA-W | FDTQ - KXE6* | FDTS - KXE6* | FDTW - KXE6* | FDT - KXE6* | FDT - KXZE1 | FDTC - KXE6* | FDU - KXE6* | FDU - KXZE1 | FDUM - KXE6* | FDUT - KXE6* | FDUH - KXE6* | FDE - KXE6* | FDE - KXZE1 | FDFW - KXE6* | FDFL - KXE6* | FDFU - KXE6* | FDK - KXE6* | FDK - KXZE1 | FDU - FKXE6* | FDT - V* | FDTC - V* | FDU - V* | FDUA - V* | FDUA - AV* | FDUM - CTB* | FDUM - V* | FDEN - V* | FDF - V*

* The asterisks stand for any character in the asterisk' position.

    File Type Version Size Read online  

ORDER CODE:

INKNXMHI001R000  Mitsubishi Heavy Industries FD and VRF systems to KNX Interface with Binary Inputs - 1 unit

INCLUDED COMPONENTS:

  • Intesis Gateway.
  • Installation Manual.

Warranty: 36 months.

Gateways for Mitsubishi Heavy Industries AC systems integration

The Intesis gateways for Mitsubishi Heavy Industries Air Conditioning systems are proven and trusted products that connect Mitsubishi Heavy Industries AC systems to the most popular Building Automation standard protocols.

The portfolio includes innovative products that allow optimal control of Mitsubishi Heavy Industries splits and VRF systems.


From the automation side, it does not matter the model of your Mitsubishi Heavy Industries unit: Residential, FD, KX6 and KXR6 series are supported with Intesis gateways. Check out your model in our HVAC compatibility tool and start working with Intesis solutions for Mitsubishi Heavy Industries air conditioner units.

Connected to


Mitsubishi Heavy Industries Indoor Units


Mitsubishi-Heavy-Industries-indoor-unit-solution-scheme
Mitsubishi-Heavy-Industries-one-to-one-Air-Conditioner-Interfaces-showcase

Your one to one solution for Mitsubishi Heavy Industries residential AC units. Direct connection from Intesis device to CNS port in AC indoor unit. Wire to CNS connector is provided.

ASCII-WiFi logo 25

Mitsubishi Heavy Industries wired remote controllers bus


Mitsubishi-Heavy-Industries-wired-remote-controller-solution-scheme
Mitsubishi-heavy-industries-remote-controller-Air-Conditioner-Interfaces-showcase

Your one to one solution for Mitsubishi Heavy Industries residential units, FD, KX6 and KXR6 series (VRF units). Direct connection to Mitsubishi Heavy Industries XY remote controller bus. AC manufacturer remote controller is optional.

*RAC Series require optional SC-BIKN-E from MHI.
BACnet logo
KNX logo
Modbus logo
ASCII-WiFi logo 25

Mitsubishi Heavy Industries Outdoor Units

Mitsubishi-Heavy-Industries-outdoor-unitsolution-scheme
700 Series for HVAC Integration

Your solution for Mitsubishi Heavy Industries VRF systems. Direct connection to MHI SuperLink internal bus. Up to 128 MHI VRF indoor units with only one Intesis gateway.

“Mitsubishi Heavy Industries Thermal Systems, Ltd.
Wholly owned subsidiary of Mitsubishi Heavy Industries, Ltd.”

BACnet logo
KNX logo
Modbus logo
ASCII-WiFi logo 25