It has never been so easy to integrate Modbus Slave devices into a KNX project. Any KNX integrator can integrate Modbus RTU Slaves or Modbus TCP Servers, or both at the same time, and translate the Modbus values to the required KNX DPT types.

KNX Modbus MBM

I/we ACCEPT/GIVE EXPRESS CONSENT. Check our Privacy Policy.

ORDER CODE: 

  • IBKNXMBM1000000 (100 points version)
  • IBKNXMBM2500000 (250 points version)
  • IBKNXMBM6000000 (600 points version)
  • IBKNXMBM1K20000 (1200 points version)
  • IBKNXMBM3K00000 (3000 points version)

 

DESCRIPTION:

IntesisBox is a Modbus RTU Master and TCP Client device allowing to read/write points of other Modbus RTU Slave device(s) and Server device(s) connected to a Modbus network, offering these point's values through its KNX/EIB interface.

From the Modbus system point of view, after the start-up process, IntesisBox reads continuously the points configured to be read in the Modbus Slave devices and updates in its memory all the values received from the Modbus system. Points of Modbus devices can be read/written from KNX at any time.


On the KNX side, IntesisBox simulates a KNX device and acts as if it was a single device into the KNX system.

The IntesisBox's KNX EIB interface connects directly to the EIB bus and it is optoisolated from the rest of the internal electronics. Any point in IntesisBox can be configured individually for different functionalities:

  • Allow read requests
  • Allow write requests
  • Automatically send a write request to the KNX bus when its value changes
  • Send a read request to the KNX bus when IntesisBox starts-up or after a KNX bus reset.

 

For each point, one KNX main group address and different listening group addresses can be defined. This useful feature allows actions on the same internal point from multiple KNX group addresses.

 

Gateway configuration is carried out using the configuration software IntesisBox® MAPS. This app allows you to create your own settings for your device. Also, it will be able to download all the available templates or to import any created/exported template on your computer. To set up, check the link below to watch de video tutorial.

 

INTEGRATION EXAMPLE:

How to use the new Modbus templates feature (video)

 

NOTE:

In case you need documentation for the previous gateway version (IBOX-KNX-MBRTU, for Modbus RTU), please check the following link:
https://www.intesisbox.com/en/modbus-rtu-knx-ibox-knx-mbrtu-discontinued/gateway/ 

In case you need documentation for the previous gateway version (IBOX-KNX-MBTCP, for Modbus TCP), please check the following link:
https://www.intesisbox.com/en/modbus-tcp-knx-ibox-knx-mbtcp-discontinued/gateway/

Modbus to KNX Gateway Integration examples

Modbus RTU and TCP to KNX Gateway Integration examples

Modbus to KNX Gateway Integration examples 568

Does your project not fit the product description, but you need to integrate the KNX and Modbus MBM protocols?

Maybe our IBOX-MBS-KNX gateway is what you are looking for.

Gateway IBOX-MBS-KNX

Modbus to KNX Gateway

downloads

  • Technical documentation