Check out our wide range of IntesisBox solutions and gateways.

IntesisBox offers a wide range of products to facilitate communication between different protocols. Based on the most used standard protocols, such as BACnet, EnOcean, KNX, LonWorks, Modbus, DALI, MBUS and many more, IntesisBox helps you integrate most of the devices currently in the market related with Home and Building automation.

Multi-protocol integration may be required in many different scenarios. From very large installations, to small projects the variety of nowadays technologies require multiprotocol integrations at all scales. Thanks to multi-protocol converters, different devices can coexist in a single management system, such as SCADA, BMS or Central Controller solutions.

Protocols are not identical, its features and design make each stand out in some applications or scenarios. For example, KNX may be clear option for homes, hotels and offices, while on the other hand BACnet or Modbus are more related to public buildings such as hospitals, airports.

IntesisBox is one of the most specialized multi-protocol gateways manufacturer. It offers a wide range of products to combine protocols for complex, functional and accurate installations. IntesisBox works and combines the following protocols: ASCII, BACnet, DALI, EnOcean, FIDELIO, KNX, LonWorks, Modbus and WiFi.

Examples of using the multi-protocol solution in different cases with IntesisBox gateways, are shown below:

Public buildings

Think of any large building such as a Hospital or a Rail Station. Nowadays control and supervision systems require lots of elements playing around to get the most of it. For instance:

  • HVAC systems
  • Fire protections systems
  • Lighting control
  • Energy meters
  • Sensors

All these elements need to talk to the central controller (BMS or SCADA) which is usually only capable of talking one single protocol, while the other elements talk its own one (even if it standard).

Is in this types of scenarios where IntesisBox multi-protocol gateways can make the most and help you integrating all these elements in a natural and simple way.

Smart homes

But multi-protocol solutions shall not be only located in large facilities. Even in a very small project, you can be in the situation of requiring a multi-protocol solution. Think of any window contact, blind actuator, light control, climate control… Again, all these devices usually use their own proprietary protocol or a standard one and in order to get them all together in your control system, you will need a multi-protocol converter to match all of them.

Automation
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
BACnet - - - - - - IBOX-MBS-BAC
- -
Modbus MBM - IBOX-BAC-MBM
- - IBOX-KNX-MBM
- - - -
Modbus RTU - IBOX-BAC-MBRTU
- - IBOX-KNX-MBRTU
- IBOX-MBS-TCP2RTU
- -
Building Management
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ASCII - - - USB-ENO-ASCII-U/C
USB-ENO-ASCII/C
- - - - -
BACnet IBOX-ASCII-BAC
- - - IBOX-KNX-BAC
- IBOX-MBS-BAC
- -
EnOcean - - - - IBOX-KNX-ENO-A1/C
- - - -
KNX IBOX-ASCII-KNX
IBOX-BAC-KNX
- - - IBOX-LON-KNX
IBOX-MBS-KNX
- -
LonWorks IBOX-ASCII-LON
- - - IBOX-KNX-LON
- IBOX-MBS-LON
- -
Modbus MBM - - - - IBOX-KNX-MBM
- - - -
Modbus RTU - - - - IBOX-KNX-MBRTU
- IBOX-MBS-TCP2RTU
- -
Modbus TCP - - - - IBOX-KNX-MBTCP
- - - -
Energy Measurement
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
M-BUS - IBOX-BAC-MBUS
- - - - IBOX-MBS-MBUS
- -
Modbus MBM - - - - IBOX-KNX-MBM
- - - -
Modbus RTU - - - - IBOX-KNX-MBRTU
- - - -
Fire Protection
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
Algorex - - - - - - IBOX-MBS-ALGOREX
- -
Algorinet - - - - - - IBOX-MBS-ALGORI
- -
Cerberus - - - - - - IBOX-MBS-CERBERUS
- -
FC330A - - - - - - IBOX-MBS-FC330A
- -
Kilsen - - - - - - IBOX-MBS-KILSEN
- -
NID3000 - IBOX-BAC-NID3000
- - - - IBOX-MBS-NID3000
IS-OPC-NID3K
-
Hotel Management
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
DALI - IBOX-BAC-DALI
- - - - - - -
Fidelio - IBOX-BAC-FID
- - - - IBOX-MBS-FID-A/B
- -
HVAC
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
Arçelik AC - - - - AK-AC-KNX-4/8/16/64
- - - -
Daikin AC - - DK-AC-BAC-1
DK-AC-ENO-1/1C
DK-AC-KNX-1i
DK-AC-KNX-1
- DK-AC-MBS-1
- DK-AC-WMP-1
Daikin RC - - DK-RC-BAC-1
DK-RC-ENO-1i/1iC
DK-RC-KNX-1i
DK-RC-KNX-1
- DK-RC-MBS-1
- DK-RC-WMP-1
Fujitsu RC - - - - FJ-RC-KNX-1i
- FJ-RC-MBS-1
- FJ-RC-WMP-1
Hisense RC - - - - - - HS-RC-MBS-1
- -
Hitachi AW - - - - HI-AW-KNX-1
- - - -
Hitachi RC - HI-AC-BAC-8/64
- - - - HI-RC-MBS-1
- -
IR - - - - IS-IR-KNX-1i
- - - IS-IR-WMP-1
LG AC - - - - LG-AC-KNX-4/8/16/64
- LG-AC-MBS-4/8/32/64
- -
LG RC - - - - LG-RC-KNX-1i
- LG-RC-MBS-1
- LG-RC-WMP-1
Midea AC - - - - MD-AC-KNX-1B/16/64
- MD-AC-MBS-1/4/8/32
- -
Mitsubishi Electric AC - - ME-AC-BAC-1
ME-AC-ENO-1/1C
ME-AC-KNX-15/100
ME-AC-KNX-1i
ME-AC-KNX-1-V2
ME-AC-LON-1
ME-AC-MBS-1
ME-AC-MBS-50/100
- ME-AC-WMP-1
Mitsubishi Heavy Ind AC - - - - MH-AC-KNX-48/128
- MH-AC-MBS-48/128
- -
Mitsubishi Heavy Ind RC - - MH-RC-BAC-1
MH-RC-ENO-1i/1iC
MH-RC-KNX-1i
- MH-RC-MBS-1
- MH-RC-WMP-1
Panasonic AC - PA-AC-BAC-64/128
PA-AC-BAC-1
PA-AC-ENO-1i/1iC
PA-AC-KNX-64/128
PA-AC-KNX-1i
- PA-AC-MBS-64/128
PA-AC-MBS-1
- PA-AC-WMP-1
Panasonic AW - - - - PA-AW2-KNX-1
PA-AW-KNX-1
- PA-AW-MBS-1
PA-AW2-MBS-1
- -
Panasonic RC - - PA-RC2-BAC-1
- PA-RC-KNX-1i
- - - -
Panasonic RC2 - - - - PA-RC2-KNX-1i
- PA-RC2-MBS-1
- PA-RC2-WMP-1
Samsung NASA AC - - - - SM-ACN-KNX-4/8/16/64
- SM-ACN-MBS-4/8/32/64
- -
Samsung NO NASA RC - - - - - - SM-RC-MBS-1
- -
Toshiba AC - - - - TO-AC-KNX-16/64
- - - -
Toshiba RC - - TO-RC-BAC-1
- TO-RC-KNX-1i
- TO-RC-MBS-1
- TO-RC-WMP-1
Intrusion Detection System
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
SIA - - - - - - IBOX-MBS-GALAXY
- -
Lighting Control
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
DALI - IBOX-BAC-DALI
- - - - IBOX-MBS-DALI
- -
Multiprotocol Integration
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ASCII - - - USB-ENO-ASCII-U/C
USB-ENO-ASCII/C
- - - - -
BACnet IBOX-ASCII-BAC
- - - IBOX-KNX-BAC
- IBOX-MBS-BAC
- -
Daikin AC - - - - - - - - DK-AC-WMP-1
Daikin RC - - - - - - - - DK-RC-WMP-1
EnOcean - - - - IBOX-KNX-ENO-A1/C
- - - -
Fidelio - IBOX-BAC-FID
- - - - - - -
Fujitsu RC - - - - - - - - FJ-RC-WMP-1
IR - - - - - - - - IS-IR-WMP-1
KNX IBOX-ASCII-KNX
IBOX-BAC-KNX
- - - IBOX-LON-KNX
IBOX-MBS-KNX
- -
LG RC - - - - - - - - LG-RC-WMP-1
LonWorks IBOX-ASCII-LON
IBOX-BAC-LON
- - IBOX-KNX-LON
- IBOX-MBS-LON
- -
M-BUS - IBOX-BAC-MBUS
- - - - IBOX-MBS-MBUS
- -
Mitsubishi Electric AC - - - - - - - - ME-AC-WMP-1
Mitsubishi Heavy Ind RC - - - - - - - - MH-RC-WMP-1
Modbus MBM - IBOX-BAC-MBM
- - IBOX-KNX-MBM
- - - -
Modbus RTU - IBOX-BAC-MBRTU
- - IBOX-KNX-MBRTU
- IBOX-MBS-TCP2RTU
- -
Modbus TCP - IBOX-BAC-MBTCP
- - IBOX-KNX-MBTCP
- - - -
Panasonic AC - - - - - - - - PA-AC-WMP-1
Panasonic RC2 - - - - - - - - PA-RC2-WMP-1
Toshiba RC - - - - - - - - TO-RC-WMP-1
Solar Power Systems
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ATERSA - - - - - - IBOX-MBS-ATERSA
- -
SUNWAYS - IBOX-BAC-SUNWAYS
- - - - - - -
Wireless Integration
ASCII BACnet BACnet BTL EnOcean KNX LonWorks Modbus OPC WiFi
ASCII - - - USB-ENO-ASCII-U/C
USB-ENO-ASCII/C
- - - - -
Daikin AC - - - - - - - - DK-AC-WMP-1
Daikin RC - - - - - - - - DK-RC-WMP-1
Fujitsu RC - - - - - - - - FJ-RC-WMP-1
IR - - - - - - - - IS-IR-WMP-1
LG RC - - - - - - - - LG-RC-WMP-1
Mitsubishi Electric AC - - - - - - - - ME-AC-WMP-1
Mitsubishi Heavy Ind RC - - - - - - - - MH-RC-WMP-1
Panasonic AC - - - - - - - - PA-AC-WMP-1
Panasonic RC2 - - - - - - - - PA-RC2-WMP-1
Toshiba RC - - - - - - - - TO-RC-WMP-1
USB - - - USB-ENO/C
- - - - -