HVAC Compatibility tool

Find the appropriate solution for your Air Conditioner brand to get the most out of your AC system.

Toshiba AC brand Solution

Find your AC integration solution developed jointly with Toshiba. Following its specifications provided ensure the compatibility as a major factor to enable maximum efficiency.
HMS_web-icon_Backup

Ensure energy savings

Intesis AC gateways allow to reduce considerably the energy consumption of buildings while contributing to environment protection.

HMS_web-icon_Solution Partner

Improve user's comfort

The goal is to reduce energy while improving user’s comfort. With Intesis these are not mutually exclusive outcomes!

fan-and-vane

Leading with leaders

We are the indisputable market leader in AC integration thanks to have the continuous support of the major AC manufacturers.

Toshiba VRF and Digital systems to KNX Interface with Binary Inputs

The Toshiba-KNX gateway allows fully bi-directional communication between Toshiba VRF and Digital systemsand KNX installations.

Additionally, four potential-free binary inputs provide the possibility to integrate external devices, such as window contacts or presence detectors, that allows launching internal functions focused to improve energy efficiency.

FEATURES

  • KNX certified.
  • Configured by ETS standard configuration tool.
  • Reduced dimensions allowing a quick installation inside the Air Conditioner unit.
  • Offered all the required DPT objects to be compatible with all KNX thermostats in the market.
  • Energy efficiency functions, such as “timeout”, “open window” or “Occupancy”. Costs related to HVAC systems in a building are one of the highest and these functions allow to reduce them.
  • Smooth integration of KNX thermostats allowing the control of the AC unit by the own temperature sensor of the thermostat.
  • Simultaneous control of the AC unit by the IR remote controller and by KNX.
  • Total control and monitoring of the AC unit from KNX, including AC unit’s internal variables, running hours counter (for filter maintenance control) and error indication.
  • Up to 5 scenes can be saved and executed from KNX.
toshiba-vrf-digital-knx-binary-inputs-interface

Use Case

Integration of Toshiba VRF & Digital systems into a KNX installation.

TO-RC-KNX-1i

Description

DIRECT CONNECTION TO INDOOR UNITS

The gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the monitoring of errors, alarms and some internal variables.

EASY TO SET UP BY ETS (STANDARD KNX TOOL)    

The connection between the two networks is quickly set up in the ETS configuration tool using the product database available to download. Thanks to the high number of supported KNX DPTs and the KNX certification, the gateway ensures interoperability with any KNX device in the market.

Technical Documentation 

User ManualGeneral information about this productDownload
Installation ManualLearn how to install the device in your projectDownload
HVAC Compatibility toolFind the appropriate solution for your HVAC integrationOpen
HVAC CompatibilityCheck your HVAC compatibilityDownload
EC Declaration of ConformityCheck the product certificationDownload
Tender Specification DocumentProduct details for tender submittalDownload

Programming Tool

ETS Data Base Configuration tool Download

Commercial Documentation

Marketing Datasheet Discover all the integration solutions for Toshiba
Download
Intesis Brochure
Know more about the Intesis current available products
Download

HVAC Compatibility

Ensure the compatibility of this gateway with your AC model by visiting https://compatibility.intesis.com/

Compatible AC models

RAV-SM - KRT-E | RAV-SM - KRTP-E | RAV-RM - KRTP-E | RAV-SM - BT-E | RAV-SM - BTP-E | RAV-RM - BTP-E | RAV-SM - DT-E | RAV-SM - DTP-E | RAV-SM - SDT-E | RAV-RM - SDT-E | RAV-SM - CT-E | RAV-SM - CTP-E | RAV-RM - CTP-E | RAV-SM - MUT-E | RAV-RM - MUT-E | RAV-SM - UT-E | RAV-SM - UTP-E | RAV-RM - UTP-E | RAV-DXC010 LC | MMU-AP - MH-E | MMU-AP - MH1-E | MMU-AP - H | MMU-AP - HP-E | MMU-AP - HP1-E | MMU-AP - YH-E | MMU-AP - YH1-E | MMU-AP - SH-E | MMU-AP - SH1-E | MMU-AP - WH | MMU-AP - WH1 | MMD-AP - BH-E | MMD-AP - BHP-E | MMD-AP - BHP1-E | MMD-AP - H-E | MMD-AP - HP-E | MMD-AP - HP1-E | MMD-AP - HFE | MMD-AP - SPH-E | MMD-AP - SPH1-E | MMC-AP - H-E | MMC-AP - HP-E | MMC-AP - HP1-E | MML-AP - BH-E | MML-AP - BH1-E | MML-AP - H-E | MML-AP - H1-E | MMF-AP - H-E | MMF-AP - H1-E | MML-AP - NH-E | MMK-AP - H | MMK-AP - H1 | MMK-AP - MH-C | MMK-AP - MH-E | MMK-AP - MH1-E | MMK-AP - MHP1-E | RAV-SE - 1CP-ID | RAV-SE - 1CP-T | RAV-SE - 1UP-ID | RAV-SE - 1UP-T | RAV-SP - UT-UL

* The asterisks stand for any character in the asterisk' position.

    File Type Version Size Read online  

ORDER CODE:

INKNXTOS001R000  Toshiba VRF and Digital systems to KNX Interface with Binary Inputs - 1 unit

INCLUDED COMPONENTS:

  • Intesis Gateway.
  • Installation Manual.

Warranty: 36 months.

Gateways for Toshiba AC systems integration

Intesis portfolio for Toshiba Air Conditioning systems ensure the perfect interconnection between the most extended protocols in Building Automation and Toshiba AC systems.

Intesis has been always working in collaboration with Toshiba taking the opportunity in this way to offer highly reliable solutions under its brand Intesis.


From the automation side, it does not matter the model of your Toshiba unit: Digital inverter and VRF AC units are supported with Intesis gateways.

Check out your model in our HVAC compatibility tool and start working with Intesis solutions for Toshiba air conditioner units.

Connected to


Toshiba wired remote controllers bus


Toshiba-AC-wired-remote-controllers-bus-solution-scheme
Toshiba-remote-controller-Air-Conditioner-Interfaces-showcase

Your one to one solution for Toshiba Digital inverter and VRF AC units. Direct connection to Toshiba AB remote controller bus. AC manufacturer remote controller is optional.

BACnet logo
KNX logo
Modbus logo
ASCII-WiFi logo 25

Toshiba centralized controllers


Toshiba-AC-centralized-controllers-solution-scheme
INKNXTOSXXXO000 Gateway

Your solution for Toshiba VRF systems. Direct connection to Toshiba TCC-Link VRF internal bus. Up to 64 Toshiba VRF indoor units with only one Intesis gateway.

KNX logo